Molina Pfennig, Pedro DanielGonzález-Baheza, Arturo2022-06-282022-06-282020-09-22https://repositorio.colson.edu.mx/handle/2012/46017The objective of the work is to assess the suitability index for photovoltaic concentrator’s installation in Baja California Sur municipalities. The methodology proposes a suitability model incorporating six spatially explicit socio-environmental indicators with assignment of their differentiated contribution or weights by multi-criteria analysis. The results show the average annual horizontal irradiation in Baja California Sur is 6.19 kW h/m2/day for the 1998-2014 period. 5.25% of the total area in the state is viable for the installation of photovoltaic concentrators. Comondú, Mulegé and La Paz showed the highest suitability values. The road network, the electricity network and areas with 4° or less slope were the predominant indicators in the model. The study was limited to analyzing the influence of socio-environmental indicators on the photovoltaic concentrator systems location. Methodology could be replicated in other regions to facilitate decision making. The results suggest that the three Baja California Sur municipalities mentioned are the most favorable in socio-environmental terms to install such concentrators.El objetivo del trabajo es evaluar el índice de aptitud de los municipios de Baja California Sur para la instalación de concentradores fotovoltaicos. La metodología propone un modelo de aptitud que incorpora seis indicadores socioambientales explícitos en términos espaciales con asignación de su contribución diferenciada o pesos por medio de análisis multicriterio. Los resultados muestran que la irradiación horizontal anual promedio en Baja California Sur es de 6.19 kW h/m2/día en el periodo 1998-2014. De la superficie total en el estado, 5.25% es viable para la instalación de concentradores fotovoltaicos. Comondú, Mulegé y La Paz presentaron los mayores valores de aptitud. Los indicadores predominantes del modelo son la red carretera, la red eléctrica y las zonas con pendientes de ˂4°. El estudio se limitó a analizar la influencia de los indicadores socioambientales en la ubicación de sistemas de concentradores fotovoltaicos. La metodología podría replicarse en otras regiones para facilitar la toma de decisiones. Los resultados sugieren que los tres municipios de Baja California Sur mencionados son los más favorables en términos socioambientales para la instalación de dichos concentradores.The objective of the work is to assess the suitability index for photovoltaic concentrator’s installation in Baja California Sur municipalities. The methodology proposes a suitability model incorporating six spatially explicit socio-environmental indicators with assignment of their differentiated contribution or weights by multi-criteria analysis. The results show the average annual horizontal irradiation in Baja California Sur is 6.19 kW h/m2/day for the 1998-2014 period. 5.25% of the total area in the state is viable for the installation of photovoltaic concentrators. Comondú, Mulegé and La Paz showed the highest suitability values. The road network, the electricity network and areas with 4° or less slope were the predominant indicators in the model. The study was limited to analyzing the influence of socio-environmental indicators on the photovoltaic concentrator systems location. Methodology could be replicated in other regions to facilitate decision making. The results suggest that the three Baja California Sur municipalities mentioned are the most favorable in socio-environmental terms to install such concentrators.El objetivo del trabajo es evaluar el índice de aptitud de los municipios de Baja California Sur para la instalación de concentradores fotovoltaicos. La metodología propone un modelo de aptitud que incorpora seis indicadores socioambientales explícitos en términos espaciales con asignación de su contribución diferenciada o pesos por medio de análisis multicriterio. Los resultados muestran que la irradiación horizontal anual promedio en Baja California Sur es de 6.19 kW h/m2/día en el periodo 1998-2014. De la superficie total en el estado, 5.25% es viable para la instalación de concentradores fotovoltaicos. Comondú, Mulegé y La Paz presentaron los mayores valores de aptitud. Los indicadores predominantes del modelo son la red carretera, la red eléctrica y las zonas con pendientes de ˂4°. El estudio se limitó a analizar la influencia de los indicadores socioambientales en la ubicación de sistemas de concentradores fotovoltaicos. La metodología podría replicarse en otras regiones para facilitar la toma de decisiones. Los resultados sugieren que los tres municipios de Baja California Sur mencionados son los más favorables en términos socioambientales para la instalación de dichos concentradores.spaDerechos de autor 2020 Pedro Daniel Molina Pfennig, Arturo González-Bahezahttps://creativecommons.org/licenses/by-nc/4.0/info:eu-repo/semantics/openAccessCiencias SocialesPhotovoltaic concentrator systemBaja California SurAlternative energiesGeographic information systemsSolar potential assessmentCoastal municipalitiesSuitability modelConcentradores fotovoltaicosBaja California SurEnergías alternativasSistemas de información geográficaEvaluación de potencial solarMunicipios costerosModelo de aptitudPhotovoltaic concentrator systemBaja California SurAlternative energiesGeographic information systemsSolar potential assessmentCoastal municipalitiesSuitability modelConcentradores fotovoltaicosBaja California SurEnergías alternativasSistemas de información geográficaEvaluación de potencial solarMunicipios costerosModelo de aptitudAssessment of Solar Radiation Resources in the Municipalities of Baja California Sur, Mexico, Using a Socio-environmental Suitability ModelEvaluación de los recursos de radiación solar en los municipios de Baja California Sur, México, mediante un modelo de aptitud socioambientalinfo:eu-repo/semantics/article